Part Number Hot Search : 
9151C SDA294K 259783 TC141 AJ211535 EPA3568S 88HF100 15020
Product Description
Full Text Search
 

To Download RPT-7512 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification model dc voltage rated current current range rated power output voltage adj. range setup, rise time hold up time (typ.) voltage range frequency range efficiency(typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload 500ms, 30ms/230vac 500ms, 30ms/115vac at full load 80ms/230vac 20ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz 1.5a/115vac 1a/230vac cold start 25a/115vac 50a/230vac 140 ~ 180% rated output power -20 ~ +70 (refer to "derating curve") 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 45 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes file name:rpt-75-spec 2012-02-20 over voltage r p t- 7 5 s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 environment safety & emc (note 4) protection 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 6. heat sink hs1,hs2,hs3 can not be shorted. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : shut down o/p voltage, re-power on to recover 76% line regulation load regulation ch1 ch1 ch1 output number features : universal ac input / full range low leakage current<200ua protections: short circuit / overload / over voltage free air convection for rated power and 23.5cfm forced air convection for peak load ansi/aami es60601-1/iec60601-1/en60601-1 medical safety app roved fixed switching frequency at 65khz 3 years warranty 75w triple output medical type 521.2k hrs min. mil-hdbk-217f (25 ) 127*76.2*31mm (l*w*h) compliance to en55011 (cispr11), en55022 (cispr22) class b, en61000 -3-2,-3 i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh ansi/aami es60601-1, tuv en60601-1, iec60601-1 approved i/p-o/p:4kvac i/p-fg:1.5kvac o/p-fg:1.5kvac peak load (23.5cfm) withstand voltage isolation resistance 0.26kg; 63pcs/17.4kg/1.35cuft rpt-75a 5v 6a 0.6 ~ 8a 6a 0.6 ~ 8a 68.5w 93w 80mvp-p ch1:4.75 ~ 5.5v 2.0% 0.5% 1.5% rpt-75b rpt-75c 12v ch2 ch2 ch2 -5v ch3 ch3 ch3 12v -12v 15v -15v 5v 5v 3a 0.2 ~ 4a 3a 0.2 ~ 4a 0.5a 0.1 ~ 1a 0.5a 0.1 ~ 1a 2.3a 0.1 ~ 3a 0.5a 0.1 ~ 1a 6a 0.6 ~ 8a 72w 100w 72w 100w 120mvp-p 120mvp-p 120mvp-p 120mvp-p 150mvp-p 150mvp-p 80mvp-p 80mvp-p 6.0% 5.0% 6.0% 5.0% 8.0% 5.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 3.0% 1.0% 3.0% 1.0% 3.0% 1.0% 2.0% 2.0% 0.5% 1.5% 0.5% 1.5% 77% 77% ch1: 5.75 ~ 6.75v earth leakage current <200ua / 264vac, patient <100ua/264vac leakage current emc immunity emc emission compliance to en61000-4-2,3,4,5,6,8,11, en55024, en60601-1- 2, en61000-6-2, en61204-3, heavy industry level, en61204-3 medica l level, criteria a
specification model dc voltage rated current current range rated power output voltage adj. range setup, rise time hold up time (typ.) voltage range frequency range efficiency(typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload 500ms, 30ms/230vac 500ms, 30ms/115vac at full load 80ms/230vac 20ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz 1.5a/115vac 1a/230vac cold start 25a/115vac 50a/230vac 140 ~ 180% rated output power -20 ~ +70 (refer to "derating curve") 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 45 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes file name:rpt-75-spec 2012-02-20 over voltage r p t- 7 5 s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 environment safety & emc (note 4) protection 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 6. heat sink hs1,hs2,hs3 can not be shorted. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : shut down o/p voltage, re-power on to recover line regulation load regulation ch1 ch1 output number features : universal ac input / full range low leakage current<200ua protections: short circuit / overload / over voltage free air convection for rated power and 23.5cfm forced air convection for peak load ansi/aami es60601-1/iec60601-1/en60601-1 medical safety app roved fixed switching frequency at 65khz 3 years warranty 75w triple output medical type 127*76.2*31mm (l*w*h) compliance to en55011 (cispr11), en55022 (cispr22) class b, en61000 -3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11, en55024, en60601-1- 2, en61000-6-2, en61204-3, heavy industry level, en61204-3 medica l level, criteria a i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh ansi/aami es60601-1, tuv en60601-1, iec60601-1 approved i/p-o/p:4kvac i/p-fg:1.5kvac o/p-fg:1.5kvac peak load (23.5cfm) withstand voltage isolation resistance 521.2k hrs min. mil-hdbk-217f (25 ) 0.26kg; 63pcs/17.4kg/1.35cuft ch1:4.75 ~ 5.5v ------ rpt-7503 rpt-75d ch2 ch2 ch3 ch3 12v 12v 24v 3.3v 5v 1a 0 ~ 1.5a 0.1 ~ 1a 1.5a 0 ~ 8a 0.1 ~ 2a 5a 0.7 ~ 7a 0.6 ~ 7a 61.8w 73w 81.1w 95w 120mvp-p 200mvp-p 120mvp-p 120mvp-p 80mvp-p 80mvp-p 6.0% 8.0% +10,-6% 8.0% 1.0% 1.0% 1.5% 1.0% +5,-4% 3.0% 6.0% 3.0% 4.0% 2.0% 1.0% 0.5% +3,-4% 1.5% 74% 79% ch1: 5.75 ~ 6.75v ch1: 3.8 ~ 4.45v 5v 1a 6a 6a earth leakage current <200ua / 264vac, patient <100ua/264vac leakage current emc immunity emc emission
mechanical specification file name:rpt-75-spec 2012-02-20 block diagram output derating vs input voltage input voltage (vac) 60hz 90 100 95 120 115 160 140 200 180 240 220 264 load (%) 90 100 80 70 60 50 40 fosc : 65khz unit:mm load (%) ambient temperature ( ) (horizontal) -20 0 10 20 30 40 50 60 70 20 50 80 100 133 convection cooling 23.5cfm forced air cooling ac input connector (cn1) : jst b3p-vh or equivalent pin no. 12 3 assignment ac/n no pin ac/l mating housing jst vhr jst svh-21t-p1.1 or equivalent or equivalent terminal cn2 3 cn1 1 2 18 7 6 4 3 25 4- 3.8 5.7 64.75 76.2 31 15cm fan 5.6 115.8 127 23.5cfm min. derating curve dc output connector (cn2) : jst b8p-vh or equivalent pin no. 1,2 3,4,5 6,7 8 assignment v1 com v2 v3 mating housing jst vhr or equivalent terminal jst svh-21t-p1.1 or equivalent 3max. ac fuse t2.5/250v hs1,hs2,hs3 can not be shorted hs2 fs2 fs1 hs1 hs3 r p t- 7 5 s e r i e s 75w triple output medical type circuit detection o.l.p. emi filter rectifiers & filter power switching filter filter filter & & & rectifiers rectifiers rectifiers +v1 +v2 v3 com i/p fg control o.v.p.


▲Up To Search▲   

 
Price & Availability of RPT-7512

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X